Standard furnaces with regulator and blower

UKS-M boiler

12-190 kW
  • UKS-M heating furnaces (upper duct) are modernized version of UKS heating furnaces that has been enjoying popularity for many years. Being standard heating furnaces they can be used with any kind of fuel and they make up an alternative for gas-fired, oil-fired and coal-fired heating furnaces of old types.
  • In this kind of heating furnaces it is possible to burn such fuels as fine coal, coal, wood, pellets and fuel mixtures as well as biomass components. They can be used in central heating systems in flat buildings, workshops, industrial buildings and public utility buildings.
  • Available power rating: 12-190 kW. UKS-M heating furnaces meet with energy-ecology standard proved with ecological certification issued by the Institute of Chemical Processing of Coal in Zabrze.
  • They are equipped to fan and microprocessor-based regulator that controls heating furnace performance. It has a huge influence on raising heating furnace efficiency, it makes handling easier, keeps temperature set point on appropriate level and controls operation of circulation pump, supposing the system was equipped to one.
Ask about a product

Basic Information

PRODUCT DESCRIPTION

Operation principles

Modern construction and system of air distribution allow to burn fine coal using “from the top” burning method. It significantly reduces environment pollution. Instead of standard control automation system and blower, heating furnaces can be equipped to draught regulator which decreases price of the device. Heating furnaces are characterised with very big furnace chamber which let on filling up fuel tank with substantial amount of fuel in comparison with other similar heating furnaces. The result is slow combustion upon single fill-up. Depending on applied fuel and control units the heating furnace works in so-called average round-clock system, which means fuel fill up takes place once a twenty four hours on average. Wide fill-up door enable loading significantly larger pieces of fuel.

Heating furnace design

Body of the UKS-M heating furnace consists of furnace chamber and heat exchanger made of high quality attested steel. Furnace is of cuboidal shape and is closed from the bottom with water grate made of attested thick-walled pipes.

In UKS-M heating furnace was equipped to heat exchanger which is located in the rear part of the body, behind the furnace and was designed as two or four upright convection ducts, depending on power rating. Such design let on obtaining effect of spontaneous cleaning of convection ducts and effect of chimney soot fallout into collection chambers which are secured by revision flaps located on a side of the furnace. Additional advantage is line of pipes (water tubes) located in the upper part of the furnace, which significantly improves heating furnace efficiency.

UKS-M heating furnaces are equipped to thermal-resistant wide furnace door and fill-up door with purpose-made thermal gasket in the front of the heating furnace body. Whole body was covered with high-grade thermal insulation which is protected by steel casing. UKS-M central heating furnaces must be installed according to standard PN-91/B-02413 and BN-71/8864-27 concerning open vent water heating installations safety and open vent expansion tank.

Fuels

Basic
  • fine coal
  • coal
  • wood
  • biomass

Price list

Check price list
Moc nominalnaWielkość powierzchni ogrzewanejCena nettoVATCena brutto
12 kWdo 90 m23 016,26 zł693,74 zł3 710,00 zł
14 kWdo 110 m23 065,04 zł704,96 zł3 770,00 zł
21 kWdo 130 m23 203,25 zł736,75 zł3 940,00 zł
25 kWdo 160 m23 430,89 zł789,11 zł4 220,00 zł
30 kWdo 200 m23 666,67 zł843,33 zł4 510,00 zł
38 kWdo 250 m24 211,38 zł968,62 zł5 180,00 zł
46 kWdo 300 m24 983,74 zł1 146,26 zł6 130,00 zł
71 kWdo 300 m28 878,05 zł2 041,95 zł10 920,00 zł
97 kWdo 300 m210 691,06 zł2 458,94 zł13 150,00 zł
130 kWdo 300 m212 780,49 zł2 939,51 zł15 720,00 zł
190 kWdo 300 m217 804,88 zł4 095,12 zł21 900,00 zł

Specifications

UKS-M boiler

Dimensions

UKS-M boiler

Control

UKS-M boiler

Control device UKS-M 12-130 kW

ST–81 temperature regulator

ST–81 temperature regulator is intended for charging CH boilers. It controls the water circulation pump, hot usable water pump and the fan. Four optional modes of the pumps operation: house heating, boiler priority, parallel pumps, summer mode. The controller is casing is adjusted to be assembled in the boiler is installation.

Functions:

  • control of the fan, CH pump and HCW pump
  • the possibility of connecting room regulator

Equipment Controller:

  • LCD display
  • CH temperature sensor and HCW sensor
  • has temperature protection (thermal overload relay)
  • panel casing for installation of the boiler, made of high quality materials resistant to high and low temperatures
  • the possibility of installation on the boiler in OM-01 casing

Control device UKS-M 190 kW

Control device SIGNUM 350

Gallery

UKS-M boiler

Video

UKS-M boiler